Dive Rite Nitek Duo User's Guide Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Using the NiTek Duo
NiTek Duo Dive Computer User Manual 15
(4) Dive profile sampling rate
(5) Salt or fresh water use
(6, 7) Maximum depth alarm
(8, 9) Maximum time alarm
(10) Metric or Imperial units of measurement
There are three “display only” option fields that change based on
how the above settings are set.
(11) Nitrox indicator: “Nitrox” is displayed if mix1 is set for
a FO2 of greater than 21 percent. If mix1 is set for 21
percent (air), nothing appears. If mix1 is in “default,” the
Nitrox indicator flashes. For more information on “default,”
see “Understanding FO2 default.”
(12) Maximum operating depth (MOD) for FO2 setting: This
is the safe operating depth (maximum) for the selected mix.
These are based on limiting PO2 factors of 1.4 or 1.6
atmospheres respectively.
(13) Maximum depth and time alarm indicators: When you
see an indicator symbol, the alarm is set to on.
Max depth symbol:
Max time symbol:
To enter dive operation:
1. Press Mode until “dive” is displayed.
2. Using the topics that follow, set up your desired dive option
settings.
3. If you want to exit dive mode, press and hold Mode for 1 to
2 seconds to return to time mode.
Setting Mix1 and Mix2 percentages
You must set the breathing mix you plan on using on your dive.
Mix1 is considered the first breathing gas you plan on using
during a dive, and mix2 is considered the second breathing gas
you are using on a dive.
Mix1 can be set for 21 to 50 percent oxygen
Mix2 can be set for 21 to 99 percent oxygen
Page view 18