Dive Rite NiTek He User Manual

Browse online or download User Manual for Scuba diving fins Dive Rite NiTek He. Dive Rite NiTek He User manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Equipment for Serious Divers®
CO8000
NiTek Q
Computer
User Manual
www.DiveRite.com
CO8000 NiTek Q Computer User Manual_Sept 19 2011
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Computer

Equipment for Serious Divers® CO8000NiTek QComputerUser Manualwww.DiveRite.comCO8000 NiTek Q Computer User Manual_Sept 19 2011

Page 2 - IMPORTANT WARNINGS

10CO8000 NiTek Q www.DiveRite.comMENUS 4. Press the B button to toggle through the selections.• CONS2 = 30/75 (default/most conservative)• CONS1 =

Page 3 - Table Of Contents

CO8000 NiTek Q www.DiveRite.com11MENUS These calculations are based on:• One atmosphere of saltwater = 33 feet (10 meters)• One atmosphere of fresh

Page 4 - PRODUCT INFORMATION

12CO8000 NiTek Q www.DiveRite.comUsing the PLAN Mode 1. Repeatedly press the A button until “PLAN” is displayed.2. Press the B button to enter the P

Page 5 - TECH SPECS

CO8000 NiTek Q www.DiveRite.com13Dive prole information is either stored in 15-second or 30-second intervals during a dive. This must be set prior t

Page 6 - USING THE NiTek Q

tion about your dive and prompts you with safety stop information and warnings, if needed. When diving, there are two screens you can toggle between,

Page 7

CO8000 NiTek Q www.DiveRite.com15The NiTek Q does not monitor breathing gas supply. You must moni-tor this yourself, on every dive, using a submersib

Page 8 - Programming Gas Mixes

16CO8000 NiTek Q www.DiveRite.comTo Change Gases Underwater1. Press the A button. The mix number will ash.2. Press the B button to select a mi

Page 9

CO8000 NiTek Q www.DiveRite.com17Altitude OperationThe NiTek Q adjusts automatically for diving at altitude. The Q monitors altitude information in a

Page 10

18CO8000 NiTek Q www.DiveRite.comDecompression Stop Violation WarningA decompression stop violation warning is triggered when you as-cend to a shallow

Page 11 - PLAN Mode

CO8000 NiTek Q www.DiveRite.com193. If the NiTek Q does not appear to be functioning properly, do not use it to dive. Return it to your authorized

Page 12 - PROFILE Mode

IMPORTANT WARNINGS 2Read this manual carefully before diving with the NiTek Q. It is imperative that you fully understand the functions and displays

Page 13 - DIVE Mode

20CO8000 NiTek Q www.DiveRite.comNormoxic or Hypoxic Trimix Upgrade InstructionsIf you have upgraded to normoxic or hypoxic Trimix, you will be progra

Page 14 - DIVE MODE

Appendix A - TRIMIX UPGRADE CO8000 NiTek Q www.DiveRite.com215. Press the B button to select your %02 for this mix. 6. Press the A button to lock i

Page 15

DIVE ModeThe DIVE computer mode is automatically entered when the computer enters the water. It begins performing its dive calculations once you desc

Page 16

CO8000 NiTek Q www.DiveRite.com23LOG ModeThe NiTek Q stores information, such as depth, time, and gases, for every dive in a log. This stored informa

Page 17

CCR Upgrade InstructionsIf you have upgraded to CCR for your NiTek Q, your computer can now be used with closed circuit rebreathers using a constant–P

Page 18 - CARE & MAINTENANCE

Your maximum operating depth (MOD) is also displayed on SET Screen One. The MOD is the safe operating depth (maximum) for the mix selected and will a

Page 19 - WARRANTY & ACCESSORIES

Custom Gradient Factor (GF) Upgrade InstructionsYour custom gradient factor upgrade allows you to set your own gradient factors. The NiTek Q automatic

Page 20 - Appendix A - TRIMIX UPGRADE

COMPASS Upgrade InstructionsNow that you have added a digital compass to your computer, it must calibrated before use. When the DIVE mode is activate

Page 21

800-495-1046www.DiveRite.comCopyright © 2011 Lamartek, Inc. dba Dive RiteThis manual is copyrighted by Lamartek, Inc. dba Dive Rite. You may not repro

Page 22

WARNINGS...

Page 23

PRODUCT INFORMATION 4CO8000 NiTek Q www.DiveRite.comFor product updates and new product release notications, SIGN UP for the Dive Rite Newsletter an

Page 24 - Appendix B - CCR UPGRADE

TECH SPECS CO8000 NiTek Q www.DiveRite.com5Specications:Algorithm: Buhlmann ZH-L16Three pre-set gradient factors: 30/75 (default), 40/100 or 75/9

Page 25

Battery and Charge Set-upYour NiTek Q uses a rechargeable Lithium polymer battery that is sealed inside the housing. You will need to check the batte

Page 26 - number will be ashing

CO8000 NiTek Q www.DiveRite.com7SURFACE ModeThe SURFACE mode is the NiTek Q’s default screen. At the surface, the computer automatically returns to t

Page 27

8CO8000 NiTek Q www.DiveRite.comMENUS Menus Dive Option SET and Display ModeThe dive option SET and display mode is where all “dive” settings are pro

Page 28 - 800-495-1046

CO8000 NiTek Q www.DiveRite.com9SET Screen Two - The NiTek Q has maximum depth and time alarms that can be set on SET Screen Two. These alarms will b

Comments to this Manuals