Page view 54
2
O ptima FX Owner’s Manual
Ch. 6 Pg. 13
Copyright, Dive Rite All Rights Reserved January 2009
“Survival” Pre-Dive Checklist
Name ____________________________________ Date __________ Time __________
Primary S/N ________ Secondary S/N ________
Sensor: S/N: (1) _________ (2) _________ (3) _________ (4) _________
Date Installed: (1) _________ (2) _________ (3) _________ (4) _________
Battery: Date Installed: Primary ___________ Secondary ___________
Usage (hrs:min) Primary _____:_____ Secondary _____:_____
Initials NOTE: Initial upon completion of each task.
_____ 1. Inspect Wing, Harness and Quick Releases for deterioration and damage.
_____ 2. Inspect DSV/Hose assembly
2
_____ 3. Check accumulated service time on CO absorbent: (hrs:min) _____:_____
_____ 4. Is remaining time sufficient for planned dive YES / NO (circle answer)
2
_____ 5. Replace CO Cartridge when necessary.
_____ 6. Inspect Canister assembly for gross assembly errors.
_____ 7. Check service time on PRIMARY Battery: (hrs:min) _____:_____
_____ 8. Is remaining time sufficient for planned dive? YES / NO (circle answer)
_____ 9. Is the Surface Interval LESS than 24 Hours? YES / NO (circle answer)
_____ 10. If YES to #8 and #9 Skip to Step #16
_____ 11. Inspect contacts on NEW battery, clean if necessary.
_____ 12. Power Up PRIMARY and the do a GO TO SLEEP (SKIP if #9 is NO).
_____ 13. Quickly Inspect battery, Battery Cap/Spring and Battery housing.
_____ 14. Clean and Add conductive lubricant when necessary.
_____ 15. Install battery positive side into Battery Housing.
_____ 16. Check service time on SECONDARY Battery: (hrs:min) _____:_____
_____ 17. Is remaining time sufficient for planned dive? YES / NO (circle answer)
_____ 18. If YES Skip to Step #22
_____ 19. Inspect battery, Battery Cap/Spring and Battery housing.
_____ 20. Clean and Add conductive lubricant when necessary.
_____ 21. Install battery positive side into Battery Housing.
_____ 22. Power on PRIMARY and SECONDARY wrist units. Record time: _____:_____
_____ 23. Verify proper solenoid operation.
_____ 24. Verify remaining Stack Time timer on SECONDARY, Correct if necessary.
_____ 25. Inspect all hand tight fittings.
_____ 26. Is Primary Handset in Sleep Mode? YES / NO (circle answer)
_____ 27. If NO shut down primary by performing a GO TO SLEEP .
_____ 28. Perform negative pressure test (30 seconds)
2
_____ 29. Open O and diluent cylinder valves.
_____ 30. Verify ADV valve operation
2
_____ 31. Verify O and diluent addition valve operations.
_____ 32. Perform positive pressure test and check operation of Loop OPV
_____ 33. Verify current calibration and Perform a new calibration when necessary.
_____ 34. Verify cylinder pressures are sufficient for planned dive.
_____ 35. Perform breathing test to verify proper set point control.
_____ 36. Record time: _____:_____, Record Pre-dive Battery usage (#36 - #22) _____:_____