Dive Rite O2ptima Owner's Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Dive Rite
Ch. 2 Pg. 6
Copyright, Dive Rite All Rights Reserved January 2009
Diluent First Stage and Connections
The diluent first stage is the Dive Rite Model RG1208. The IP (intermediate pressure) should
be set to factory standards of 140 psi (9.7 Bar). The normal configuration from the factory is a
LP feed connected to a 3 port manifold, a LP inflator for the manual diluent addition valve, a
first stage over-pressure valve (OPV), and a submersible pressure gauge. The manifold feeds a
gas cut-off valve for the ADV, a Dive Rite RG1215 second stage and a “spare” port for a LP
inflator to supply a wing.
Warning!!
The OPV located on the diluent First stage should never be removed.
The second stage is the primary pressure release mechanism with the
OPV for failsafe protection. This is an important piece of safety
equipment should the HP seat of the first stage fail. The LP hoses can
not withstand the high pressures as supplied from the cylinder and
will cause a hose rupture. Large volumes of gas may be forced into
the counter-lungs through ADV (when enabled) causing a change in buoyancy and possible injury.
Diluent Side Assembly as supplied by the factory
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 57 58

Comments to this Manuals

No comments